TECHNICAL INFORMATION

X

 

Type of Signs

Section

 

Illuminance Categories and Illuminance Values for Generic Types of Activities in interiors As per IESNA

Type of Activity

Illuminance

Category

Ranges of Illuminance

Reference work plane

Lux

Foot-candles

Public spaces with dark surroundings

A

20-30-50

2/3/05

General Lighting Throughout spaces

Simple orientation for short temporary visits

B

50-75-100

5-7.5-10

Working spaces where visual tasks are only occasionally performed

C

100-150-200

10/15/20

Performance of visual tasks of high contrast or large size

D

200-300-500

20-30-50

Illuminance on task

Performance of visual tasks of medium contrast or small size

E

500-750-1000

50-75-100

Performance of visual tasks of low contrast or very small size

F

1000-1500-2000

100-150-200

Performance of visual  tasks of low contrast and very small size over a prolonged period

G

2000-3000-5000

200-300-500

Illuminance on task obtained by a combination of general and local (supplementary lighting)

Performance of very prolonged and exacting visual task

H

5000-7500-10000

500-750-1000

Performance of very special visual tasks of extremely low contrast and small size

I

10000-15000-20000

1000-1500-2000

 

 

Year - 2002/2003