H2
Product Number |
Multi-Mounting
Bulkhead Hazardous HID Indoor or Outdoor
Luminaire "Filter Guard" with Diffuser or
Reflector
-
(Licensed
by General Electric)
|
|
 |
|
APPLICATIONS |
 |
*
Ideal for industries, refineries, pump stations, storage areas &
others alike application that requires
protection against
present of flammable materials.
|
|
 |
|
SPECIFICATION FEATURES
|
 |
|
Design:
|
* Body is made of die cast low copper
alum. alloys, electro-epoxidized gray finish.
|
|
* Glass globe-
diffuser
is held to the
body by means of Stainless steel
fastener and
supplied w/ gasket to seal out gas, dust and water
entry.
|
|
Type of
Protection: |
|
* Temperature
Classification: T1, T2, T2A, T2B, T2C, T2D, T3, T3A, T3B, T3C,T4,
T4A, T5 &T6.
* For
detailed information refer General Electric Catalogue. |
|
|
Certificate of Conformity: |
|
* UL844 Listed:
-Class l, Div'n. 2, Grp. A, B, C & D. -Class ll, Div'n. 1 Grp. E, F
& G. -Class ll, Div'n. 2, Grp. G. -Class lll, Div'n.1 & 2 |
|
* UL1572 Listed:
-General Non-Hazardous. -Suitable for Wet Location.-For MH lamps in
polymetric lamp containment barriers. |
|
*
UL1572 Outdoor Salt Water Marine Listed: |
|
-Outdoor Salt Water
Marine (formerly UL595). |
|
-Meets NEMA 4X
Standards & IP65 Standards. |
|
Permissible
Amb. Temp. |
|
* 40°C, 55°C or 65°C
(depending on lamp, bowl-diffuser and Temperature "T" class
rating requirements). |
|
|
Mounting:
|
*
Ceiling Direct:
H2CDE
=¾" &
H2CDG
=1", Conduit
|
* Pendant Flexible:
H2PFE
=¾" &
H2PFG
=1", Conduit
|
* Pendant High Profile:
H2PHE
=¾" &
H2PHG
=1", Conduit
|
* Pendant Low Profile:
H2PLE
=¾" &
H2PLG
=1", Conduit
|
* Stanchion Angle:
H2SAI
=1¼" &
H2SAK
=1½" NPT pipe
|
* Stanchion Straight:
H2SSI
=1¼" &
H2SSK
=1½" NPT pipe
|
* Wall Arm:
H2WAE
=¾" &
H2WAG
=1", Conduit
|
|
|
Cable Entry:
|
* ¾" or 1" conduit, 1¼" or 1½" NPT pipe for cables
entry.
|
* Fixture's selection refer Mounting system.
|
|
|
Lamps:
|
* 1
-400W max., Mercury Vapor "MV" elliptical lamp.
|
* 2
&
3
-400W max., Metal Halide "MH" (elliptical & tubular)
lamp.
|
* 4
&
5-400W
max., High Pressure Sodium "HPS" (elliptical & tubular) lamp.
|
* Lamp's application refer General Electric
Catalogue.
|
|
|
Rated
Volt.: |
|
* 120, 240 or 240 VAC, 60Hz*
Other Volt./Freq.cy upon request.
|
|
Light
Controller: |
* GG1
-Glass Globe H=9"+Guard, 250W maximum.
|
* GG2
-Glass Globe H=7"+Guard, 175W maximum.
|
* GGSDR1
-Gls. Glb. H=9"+Grd+Small Dome Refl, 250W max
|
* GGSDR2
-Gls. Glb. H=7"+Grd+Small Dome Refl, 175W max
|
* GGDDR1
-Glass Glb. H=9"+Grd+Dp. Dome Refl, 250W max
|
* GGDDR2
-Glass Glb. H=7"+Grd+Dp. Dome Refl, 175W max
|
* GGADR1
-Gls.Glb. H=9"+Grd+Angle Dome Refl, 250W max
|
* GGADR2
-Gls. Glb. H=7"+Grd+Angle Dome Refl, 175W max
|
* GRG1
-Glass Refractor Ø =12" x H=10⅛"+Guard, 400W max
|
* GRG2
-Glass Refractor Ø =8" x H=7½"+Guard, 175W max.
|
* ARG1
-Acrylic Refractor Ø =12" x H=9½"+Guard, 150W max
|
* PRG1
-PC Refractor Ø =12" x H=9½"+Guard, 150W max.
|
* ERA1
-Enclosed Reflector with ALGLAS Finish, 400W max.
|
* ERAG1
-Enclosed Refl. w/ ALGLAS finish+Guard, 400W max
|
* UGRG1
-Univ'l. Glass Refr. Ø =10½" x H=8"+Grd, 175W max
|
* For detailed information refer General Electric
Catalogue
|
|
|
 |
|
|
 |
H2
Product Number |
IP-55
Protection Rating |
H
Section |
|
Tabulation
& Ordering Number Logic |
|
|
 |
Ordering
example:
H2CDE/5-150AN.GGSDR2.FU, Ceiling
direct mounted bulkhead hazardous Indoor or outdoor
luminaire ¾" conduit cable entry,
1x150-watts
High pressure sodium lamp,
AN ?120V/60Hz
Auto-regulator type, High power Factor control gear,
GGSDR2
-GlAss
Globe
H=7" + Guard + Small Dome Reflector, 175W max and
FU
-Fuser terminal block. |
|
|
|
Product
Number |
Light Source, (HID
Lamps) |
Volt./
Freq.
& Blst.
Type |
Light Controller |
Other
Option |
Dimensions
- (mm) |
Wt. |
|
No.
|
Code |
Watt. |
Globe
H=(inches), A &
B |
kg.
(app.) |
|
xxxxx/ |
- |
x- |
xxx. |
x
&
x. |
xxxxxx.
|
xx.
&/or xx. |
7 |
8 |
8¼ |
9 |
9½ |
10⅛ |
|
H2CDE |
1 |
1 |
100 |
A-120V/60Hz |
GG1
-250W
|
A1 -Auxiliary 150 |
298 & 308 |
314
& 399 |
302
& 321 |
337
&
346 |
352
& 399 |
368
& 399 |
Variable |
|
H2CDG |
175 |
C-277V/60Hz |
GG2
-175W |
W
Halogen lamp |
Variable |
|
H2PFE |
250 |
D-240V/60Hz |
GGSDR1-250W |
with
50-250 HID |
Variable |
|
H2PFG |
400 |
|
GGSDR2-175W |
wattage |
Variable |
|
H2PHE |
2 |
100 |
P
-
Reactor |
GGDDR1-250W |
|
298 & 308 |
314
& 399 |
302
& 321 |
337
&
346 |
352
& 399 |
368
& 399 |
Variable |
|
H2PHG |
175 |
N - Auto-Reg. |
GGDDR2-175W |
A2 -Auxiliary 250 |
Variable |
|
H2PLE |
2
or
3 |
250 |
O
-Mag.-Reg. |
GGADR1-250W |
W
Halogen lamp |
Variable |
|
H2PLG |
400 |
|
GGADR2-175W |
with
400 HID |
Variable |
|
H2SAI |
4
or
5 |
50 |
|
GRG1
-400W |
wattage |
298 & 308 |
314
& 399 |
302
& 321 |
337
&
346 |
352
& 399 |
368
& 399 |
Variable |
|
H2SAK |
70 |
|
GRG2