H2
Product Number

Multi-Mounting Bulkhead Hazardous HID Indoor or Outdoor
 Luminaire "Filter Guard" with Diffuser or Reflector  
-
(Licensed by General Electric)

APPLICATIONS

* Ideal for industries, refineries, pump stations, storage areas & others alike application that requires  protection against present of flammable materials.

SPECIFICATION FEATURES
Design:

* Body is made of die cast low copper alum. alloys, electro-epoxidized gray finish.

* Glass globe- diffuser is held to the body by means of Stainless steel fastener and supplied w/ gasket to seal out gas, dust and water entry.
Type of
 Protection:

* Temperature Classification: T1, T2, T2A, T2B, T2C, T2D, T3, T3A, T3B, T3C,T4, T4A, T5 &T6. * For detailed information refer General Electric Catalogue.

Certificate of Conformity:

* UL844 Listed: -Class l, Div'n. 2, Grp. A, B, C & D. -Class ll, Div'n. 1 Grp. E, F & G. -Class ll, Div'n. 2, Grp. G. -Class lll, Div'n.1 & 2

* UL1572 Listed: -General Non-Hazardous. -Suitable for Wet Location.-For MH lamps in polymetric lamp containment barriers.

* UL1572 Outdoor Salt Water Marine Listed:

-Outdoor Salt Water Marine (formerly UL595).

-Meets NEMA 4X Standards & IP65 Standards.

Permissible
Amb. Temp.

* 40°C, 55°C or 65°C (depending on lamp, bowl-diffuser and Temperature "T" class rating requirements).

Mounting:

* Ceiling Direct: H2CDE =¾" & H2CDG =1", Conduit   

* Pendant Flexible: H2PFE =¾" & H2PFG =1", Conduit

* Pendant High Profile: H2PHE =¾" & H2PHG =1", Conduit

* Pendant Low Profile: H2PLE =¾" & H2PLG =1", Conduit

* Stanchion Angle: H2SAI =1¼" & H2SAK =1½" NPT pipe

* Stanchion Straight: H2SSI =1¼" & H2SSK =1½" NPT pipe

* Wall Arm: H2WAE =¾" & H2WAG =1", Conduit

Cable Entry:

* ¾"  or 1" conduit, 1¼" or 1½" NPT pipe for cables entry.

* Fixture's selection refer Mounting system.

Lamps:

*  1 -400W max., Mercury Vapor "MV" elliptical lamp.

*  2 & 3 -400W max., Metal Halide "MH" (elliptical & tubular) lamp.

*  4 & 5-400W max., High Pressure Sodium "HPS" (elliptical & tubular) lamp.

* Lamp's application refer General Electric Catalogue.  

Rated Volt.:
* 120, 240 or 240 VAC, 60Hz* Other Volt./Freq.cy upon request.
Light
 Controller:

* GG1 -Glass Globe H=9"+Guard, 250W maximum.

* GG2 -Glass Globe H=7"+Guard, 175W maximum.

* GGSDR1 -Gls. Glb. H=9"+Grd+Small Dome Refl, 250W max

* GGSDR2 -Gls. Glb. H=7"+Grd+Small Dome Refl, 175W max

* GGDDR1 -Glass Glb. H=9"+Grd+Dp. Dome Refl, 250W max

* GGDDR2 -Glass Glb. H=7"+Grd+Dp. Dome Refl, 175W max

* GGADR1 -Gls.Glb. H=9"+Grd+Angle Dome Refl, 250W max

* GGADR2 -Gls. Glb. H=7"+Grd+Angle Dome Refl, 175W max

* GRG1 -Glass Refractor Ø =12" x H=10⅛"+Guard, 400W max

* GRG2 -Glass Refractor  Ø =8" x H=7½"+Guard, 175W max.

* ARG1 -Acrylic Refractor Ø =12" x H=9½"+Guard, 150W max

* PRG1 -PC Refractor Ø =12" x H=9½"+Guard, 150W max.

* ERA1 -Enclosed Reflector with ALGLAS Finish, 400W max.

* ERAG1 -Enclosed Refl. w/ ALGLAS finish+Guard, 400W max

* UGRG1 -Univ'l. Glass Refr. Ø =10½" x H=8"+Grd, 175W max

* For detailed information refer General Electric Catalogue

 

  

H2

Product Number

IP-55

Protection Rating

H

Section

Tabulation & Ordering Number Logic

 

Ordering example: H2CDE/5-150AN.GGSDR2.FU, Ceiling direct mounted bulkhead hazardous Indoor or outdoor luminaire ¾" conduit cable entry, 1x150-watts High pressure sodium lamp, AN ?120V/60Hz Auto-regulator type, High power Factor control gear, GGSDR2 -GlAss Globe H=7" + Guard + Small Dome Reflector, 175W max and FU -Fuser terminal block.

 

Product

Number

  Light Source,    (HID Lamps)

Volt./ Freq.         &         Blst. Type

Light Controller

Other Option

Dimensions - (mm)

Wt.

No.

Code

Watt.

Globe H=(inches),  A & B

 kg.

(app.)

xxxxx/

-

x-

xxx.

x & x.

xxxxxx.

xx. &/or xx.

7

8

9

10

H2CDE

1

1

100

A-120V/60Hz

GG1 -250W

A1 -Auxiliary 150

 298   &  308

314   &  399

302    &  321

337   & 346

352   &  399

368   &  399

Variable

H2CDG

175

C-277V/60Hz

GG2 -175W

W Halogen lamp

Variable

H2PFE

250

D-240V/60Hz

GGSDR1-250W

with 50-250 HID

Variable

H2PFG

400

 

GGSDR2-175W

wattage

Variable

H2PHE

2

100

P - Reactor

GGDDR1-250W

 

 298   &  308

314   &  399

302    &  321

337   & 346

352   &  399

368   &  399

Variable

H2PHG

175

N - Auto-Reg.

GGDDR2-175W

A2 -Auxiliary 250

Variable

H2PLE

2 or 3

250

O -Mag.-Reg.

GGADR1-250W

W Halogen lamp

Variable

H2PLG

400

 

GGADR2-175W

with 400 HID

Variable

H2SAI

4 or 5

50

 

GRG1 -400W

wattage

 298   &  308

314   &  399

302    &  321

337   & 346

352   &  399

368   &  399

Variable

H2SAK

70

 

GRG2 -175W